UNISYST ® Instrumentation & Process Control Systems
ENGINEERING LTD Bulgaria, 1756 Sofia, Darvenitza, bl. 15, ent. G, fl. 1, tel. (+359) 2 8860 562, 2 8861 203, 2 8863 237;
The measuring ranges are defined during the flowmeter setting-up, depending on diaphragm calculations and the transducers used.
Electronic counters capacity:hourly: max. reading 999 999 nm3per shift and daily: max. reading 99 999 999 nm3monthly: max. reading 9 999 999 999 nm3total: max. reading 999 999 999 999 nm3Time counter capacity: 999 999 999 999 h.
CF 300 SERIES
CF 300 D MICROPROCESSOR GAS FLOWMETER
- Input channels measuring: < ±0,1%- Calculation of corrective factor: < ±0,15%Additional error due to fluctuations of ambient temperature: Entered in the Bulgarian State Register of Licensed Measuring Instruments
Additional error due to supply voltage fluctuations: < ±0,05%.
Sofia, 2007
The flowmeter takes into account the measured and calculated CF 300 D MICROPROCESSOR GAS FLOWMETER
parameters and compares their values with the pre-set technological limits. In case any of these limits is reached, the unit generates an FUNCTION AND USE
The CF 300 D flowmeter is intended for use in all branches of The flowmeter is equipped with an alpha-numeric liquid cristal industry where measuring of gas flow is required. The process of gas display, a keyboard and two electro-mechanical counters. The unit flow measuring is effected through the measuring of the pressure drop memory stores the values of corrected and non-corrected flow for on a diaphragm with subsequent automatic correction of the errors the past 50 months, 50 days, 50 shifts and the past 200 hours, as due to the influence of gas temperature and pressure (According to well as the registered maximum values for an hour, shift, day and the Method 949- 82 of the Chief Commission for Standardization).
The unit is manufactured in two modifications: CF 300 D1 and CF The momentary gas flow value also comes out on an analog 300 D2, which differ in their construction only, the first being intended for mounting on a panel and the second for mounting on a wall.
The in-built software of the flowmeter enables its setting, The in-built RS232 interface enables the unit to be connected to a calibration and testing. The input setting parameters are stored in computer flow register system or to the specialized PU 300 printing SPECIFICATIONS
PRINCIPLE OF OPERATION
Input channels:4 galvanically separated analog inputs 4 - 20 mA with The value of the gas volume flow when measured with a an option for internal 24V DC supply for two-wire transducers. diaphragm is proportional to the square root of the gas pressure drop Optionally, CF 300 D is supplied with temperature inputs for direct on the diaphragm and is influenced by the gas temperature, pressure connection to thermoresistors Pt 100 (BSS or DIN 43760), Pt 46 The input parameters, necessary for the calculation of the gas Momentary flow: galvanically separated analog output 0(4) - 20 mA with load resistance Rl < 500Ω.
External counters and alarm: relay outputs 48V/ 1A, normally DP - pressure drop (input channel DP1 or DP2, depending on the magnitude of the measured value and the preset measuring ranges of According to the accepted Method 949-82 the measuring error Monophase electric mains, grounded, 220V (187-242V)/50Hz.
increases with the decrease of flow to less than 30% of the max. value for which the diaphragm has been calculated, and this corresponds to 9% of the max. pressure drop. The accuracy of measuring can be kept 96 x 96 x 180 mm CF 300 D1 and 213 x 180 x 100 CF 300 D2 high if two pressure-drop transmitters with different measuring ranges are used, e.g. 1 : 10. In this case an error increase shall take place only when the pressure drop comes below 0,81% of its max. value. IP 54 for CF 300 D2 and IP 20 for CF 300 D1.
The calculation of the momentary flow is performed by the use of formulae, recommended by the accepted Method 949-82, whereas the DP channel is automatically selected by the unit, depending on the Relative humidity: up to 80% at 25°CTime for initial setting: 30 min.

Source: http://www.unisyst.bg/downloads/downloads_upload/CF300D_A4.pdf

Compulsive gambling litigation: casinos and the duty of care

GAMING LAW REVIEW AND ECONOMICS Volume 13, Number 5, 2009 ©Mary Ann Liebert, Inc. DOI: 10.1089/glre.2009.13503 C ASINOS THROUGHOUT the world have been sued other countries following suit. In the past decade, for negligence because they breached an al-there has been litigation by self-excluded compul-leged duty of care to patrons. One major duty ofsive gamblers in common law jurisdictio

ftp.co.hinds.ms.us

HINDS COUNTY -- CLAIMS DOCKET FOR: 02/19/2013HINDS COUNTY CLAIMS NUMBERED _____________ LESS CLAIMS __________HINDS COUNTY CLAIMS NUMBERED __________________________HINDS COUNTY CLAIMS NUMBERED __________________________HINDS COUNTY CLAIMS NUMBERED __________________________HINDS COUNTY CLAIMS NUMBERED __________________________HINDS COUNTY CLAIMS NUMBERED __________________________HINDS CO